Automatic Digital Type 3500Hz Spark Test Machine Wire Cable Making Machine
Product Details:
Place of Origin: | China |
Brand Name: | I-suntop |
Certification: | SGS |
Model Number: | GF-15 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1set |
---|---|
Price: | By negotiation |
Packaging Details: | Plastic film+wooden box |
Delivery Time: | Min.30working days |
Payment Terms: | L/C,T/T |
Supply Ability: | Up to different machine |
Detail Information |
|||
Usage: | Spark Test | Material: | Stainless Steel |
---|---|---|---|
Application: | Wire And Cable | Warranty: | 1year,longtime Maitenance |
Voltage: | 200-240V AC 50/60Hz | Output Voltage: | 15kv |
Highlight: | digital type Spark Test Machine,3500Hz wire cable making machine,digital type wire cable making machine |
Product Description
Digital Type High Frequency Spark Test Machine For Wire And Cable
i-suntop Electric wire and cable equipments2022022...
1. Application for Wire And Cable Spark Test Machine
Test Voltage:1.0~15.0KV. Cable Diameter: 0~25mm. Output Frequency: 2.5-3.5KHz normal. Fast recovery time after fault (0.1s)
The Spark Tester is a fast and reliable instrument used in distinguish wire faults and detecting bare wires. Its high-speed fault detection feature gives you prompt information without worsening the condition of the wire after the test.
The use of high frequency (3KHz) enables a traditional commercial power frequency bead chain electrode to be shortened to 120mm HS015E Model.
2. Features for Wire And Cable Spark Test Machine
- Fast recovery time after fault (0.1 second).
- Occupies short space in line and with improvement factor of 50 compared to
- traditional CT power frequency electrode.
- Voltage Display: 0.0~15.0KV digit, 14.2mm LED display, Accuracy +/- 1% of reading
- Output Control: Front Panel Reset in Manual Mode. Closure time is selectable
- 0.2s/2s/5s in main board by jumper JP, Form C relay contacts (250VAC/5A) for all
- wire faults detected.
- Limits the fault current without damaging the test equipment.
- Short exposure time to corona does not degrade nor damage good insulation.
- Distinguishes all wire faults and detects bare wire.
- Safety Switch interlock.
3. Mian Paramters for Spark Test Machine
Output Voltage: | 0 - 15KV |
Output voltage regulation range: | 0.1 ~ 15KV, 100V per adjustment; |
Defect Records: | up to 999 records; |
MAX Diameter of Cable: | 25mm |
Test frequency: | 2500 ~ 3500Hz, varying with theequivalent load capacitance; |
Electrode: | beads-style, meet UL1581 standards; |
Electrode length: | 50mm; |
Test mode: | manual, automatic; |
Automatic leak detection recovery time: | < 20ms; |
Output current: | 4mA for resistive load, 40mA for capacitive load |
Max line speed allowed: | 3067m/min, meet BS5099 standards; 1000m/min, meet UL1581 standards; |
Output relay's capacity: | 2A, 250VAC; |
Serial communication: | RS232/422 optional; |
Max communication distance: | 300m; |
The cover of electrode has safe lock; | |
Power supply: | 200 - 240VAC, 50/60Hz; |
Environmental temperature: | -5℃~ 50℃ |
Relative humidity: | 20% ~ 85%; |
Power consumption: | ≤150W; |
Weight: | about 13 kg. |