50Hz Fiber Optic Cable Crush Testing Equipment
Product Details:
Place of Origin: | China |
Brand Name: | I-suntop |
Certification: | SGS |
Model Number: | GFK-10 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1set |
---|---|
Price: | By negotiation |
Packaging Details: | Plastic film+wooden box |
Delivery Time: | Min.50working days |
Payment Terms: | L/C,T/T |
Supply Ability: | Up to different machine |
Detail Information |
|||
Item: | Fiber Optic Cable Crush Test Equipment | Application: | Fiber Optic Cable Testing |
---|---|---|---|
Standards: | IEC60794-1-2 | Color: | Customized |
Wavelength: | 1310/1550nm | Warranty: | 1 Year |
Operating Temperature: | +25-35 Degree Centegrate | Power Supply: | 220v |
Highlight: | Optical Cable Crush Tester Machine,Optical Cable Crush Test Equipment,Fiber Optic Cable Testing Device |
Product Description
IEC-60794-1-2 Standard Fiber Optic Cable Crush Test Equipment
I-suntop Optical cable mechanical testing equipmen...
1. Application of IEC-60794-1-2 Standard Fiber Optic Cable Crush Test Equipment:
Fiber optic cable crush test equipment meets the requirements of IEC-60794-1-2 Method E3/E12,According to the detailed specifications, the cable is placed under compression and then the fiber is attenuated.
It uses a servo control system to apply compressive force to the cable at a constant speed and maintain compression for a specific period of time.
The plate is mounted on the bottom of the movable crosshead to allow the cable sample to be crushed
A crushing force is uniformly applied between the steel substrate and the movable steel plate over the length of the sample.
2. Main Technical Specifications of IEC-60794-1-2 Standard Fiber Optic Cable Crush Test Equipment:
Item | spec. |
Product model |
GFK-10 |
Max load |
10KN |
Load measurement range |
(1%~100%) F.S. |
Load resolution |
±250000 yard,no stepping, no change in full scale,resolution unchanged |
Load accuracy |
±0.5% |
Load duration |
≥3 Hours, set arbitrarily |
Load hold accuracy |
±0.5% |
Displacement resolution |
0.001mm |
Displacement control resolution |
0.00002mm |
Displacement speed range |
(0.01~500) mm/min,set arbitrarily |
Displacement speed accuracy |
±0.5% |
Distance of travel |
200mm |
Compression platen |
(100×100) mm, hardness HB240~280 |
Max diameter of clamping optical cable |
30mm |
Equipment weight |
About 180kg |
3. Factory Installation requirements of IEC-60794-1-2 Standard Fiber Optic Cable Crush Test Equipment:
- Host power supply: single phase, AC220V±10%, 50~60Hz, 0.8kW.
- Computer power supply: single phase, AC220V±10%, 50~60Hz, 0.5kW.
- Install onto a stable base, levelness≤0.2/1000, and room of more than 1 m around.
- Ambient temperature: 25℃±10℃, humidity: ≤80% non-condensing.
- No vibrating or corrosive media indoor
4. Other related test equipments: